LN2 Plant – 50LPH (StirLIN-4)
Chiller
Cooling capacity | 48 kW |
Refrigerant | R407C |
Suction/Discharge pressure | 4.2/14 barg |
Suction temperature | 11.7℃ |
Cryogenerator
Cryogenerator power | 45 kW |
Production capacity | 50 lph |
Refrigeration capacity | 4.4 kW@65K |
Working gas | Helium |
Filling pressure | 22 barg@50Hz |
Liquid nitrogen purity | >99% |
Air compressor
Compressor type | Screw |
Motor power | 25 |
Max Working pressure | 12 barg |
LN2 Plant – 100LPH (StirLIN-8)
Chiller
Cooling capacity | 108 kW |
Refrigerant | R410A |
Suction/Discharge pressure | 10/27 barg |
Suction temperature | 11.7℃ |
Cryogenerator
Cryogenerator power | 90 kW |
Production capacity | 100 lph |
Refrigeration capacity | 8.8 kW@65K |
Working gas | Helium |
Filling pressure | 22 barg@50Hz |
Liquid nitrogen purity | >99% |
Air compressor
Compressor type | Screw |
Motor power | 45 |
Max Working pressure | 12 barg |
Liquid Helium Plant :
Produces liquid helium from helium gas. Liquid helium can be used for cooling down to 2 K.
Caution
Users are instructed to bring their own containers and with some liquid helium in the container.
- Liquid Nitrogen Plant :
The Stirling Liquid Nitrogen plant (StirLIN-4) is used to produce liquid nitrogen. The nitrogen is separated from compressed ambient air (consisting of 78 % nitrogen) using adsorption desorption process. Subsequently, the nitrogen is condensed and stored as liquid in storage container under positive pressure.
-
- Main parts of helium plant
- Air compressor
- Air vessel
- Dryer
- Pressure Swing Adsorption system
- Nitrogen Vessel
- Cryogenerator
- Dewar
- Main parts of helium plant
- Liquid Helium Plant :
Liquefier (Cold Box)
The process gas (Helium) compressed and isentropic expansion in an open cycle via Turbo-Expanders until the Helium temperature falls below inversion temperature. Then isenthalpic expansion in Joule-Thomson device and helium gas is liquefied, stored in dewar at slightly above atmospheric pressure.
-
- Main parts of helium plant
- Recirculation compressor
- Oil removal System
- Buffer Vessel
- Cold Box
- Dewar
- Recovery gas bag
- Recovery compressor
- Dryer
- Helium Storage Cylinders
- Main parts of helium plant
The users are requested to apply in IRCC central facility registration (https://drona.ircc.iitb.ac.in/NewFac/CentralFacilityIndex.jsp?facilityCode=ME007) either before coming to collect the liquid nitrogen or at the time of collection. Faculties, Students, Project staff can apply in this portal. As of now Institute staff are not allowed. For the students who are not able to apply, can ask their friends to lab mates to apply and choose the faculty of the students who required LN2. In the mean time they can mail software@ircc.iitb.ac.in their issue & get it rectified.